- #27795 Human ANGPTL8 Assay Kit - IBL
Product Search
#27795 Human ANGPTL8 Assay Kit - IBL
- Intended Use:
- Research reagents
- Measuring Method:
- ELISA
- Sample Types:
- Human
- Measuring Samples:
- Serum, EDTA-plasma, Cell culture supernatant
- Measurement Range:
- 0.61 - 80 pmol/L
- Package Size1:
- 96 Well
※ The product indicated as "Research reagents" in the column Intended Use cannot be used
for diagnostic nor any medical purpose.
※ The datasheet listed on this page is sample only. Please refer to the datasheet
enclosed in the product purchased before use.
Product Overview
Product Overview
Product Code | 27795 |
---|---|
Product Name | Human ANGPTL8 Assay Kit - IBL |
Maker Name | Immuno-Biological Laboratories Co., Ltd. |
Intended Use | Research reagents |
Measuring Method | ELISA |
Conjugate | HRP |
Species | Human |
Measuring Samples | Serum, EDTA-plasma, Cell culture supernatant |
Measurement Range | 0.61 - 80 pmol/L |
Primary Reaction | 60 minutes at 37 ℃ |
Secondary Reaction | 30 minutes at 2 - 8 ℃ |
Specificity | Substance Cross reactivity (%) Human ANGPTL8 100 Human ANGPTL2 ≦0.1 Human ANGPTL3 ≦0.1 Human ANGPTL4 ≦0.1 Human ANGPTL6 ≦0.1 |
Storage Condition | 2 - 8 ℃ |
Poisonous and Deleterious Substances | Not Applicable |
Cartagena | Not Applicable |
Measuring Service | Available |
Package Size 1 | 96 Well |
Product Description
Product Description
Angiopoietin-like protein 8 (ANGPTL 8) is a protein consists of 198 amino acid that is secreted mainly from liver and fatty tissue.
It has been also known as Betatrophin, Lipasin, refeeding induced fat and liver (RIFL) and TD 26.
It is classified as an atypical ANGPTL family as ANGPTL8 is high homologous with N-terminal domain of ANGPTL3 and ANGPTL4 although it does not have a C-terminal fibrinogen-like domain which is common to ANGPTL family.
Is has been observed that triglycerides level become lower in plasma sample of ANGPTL8 deficient mice compare to the level in wild type mice after feeding while it has been reported that triglycerides level in plasma sample is elevated only if ANGPTL8 is overexpressed in presence of ANGPTL3.
It has been considered that it becomes a targeted molecule for improving current drug of hyperlipidemia or as a biomarker of metabolic diseases as ANGPTL8 is a lipoprotein regulatory factor that inhibits LPL activity through activation of ANGPTL3.
This ELISA kit can measure full length of ANGPTL8 in human samples.
It has been also known as Betatrophin, Lipasin, refeeding induced fat and liver (RIFL) and TD 26.
It is classified as an atypical ANGPTL family as ANGPTL8 is high homologous with N-terminal domain of ANGPTL3 and ANGPTL4 although it does not have a C-terminal fibrinogen-like domain which is common to ANGPTL family.
Is has been observed that triglycerides level become lower in plasma sample of ANGPTL8 deficient mice compare to the level in wild type mice after feeding while it has been reported that triglycerides level in plasma sample is elevated only if ANGPTL8 is overexpressed in presence of ANGPTL3.
It has been considered that it becomes a targeted molecule for improving current drug of hyperlipidemia or as a biomarker of metabolic diseases as ANGPTL8 is a lipoprotein regulatory factor that inhibits LPL activity through activation of ANGPTL3.
This ELISA kit can measure full length of ANGPTL8 in human samples.
References
References
- Plasma ANGPTL8 Levels and Risk for Secondary Cardiovascular Events in Japanese Patients With Stable Coronary Artery Disease Receiving Statin Therapy. Morinaga J et al. Arterioscler Thromb Vasc Biol. 2023 Jun 1.PMID: 37259862
- ANGPTL8 links inflammation and poor differentiation, which are characteristics of malignant renal cell carcinoma. Matsukawa T et al. Cancer Sci. 2022 Dec 18.PMID: 36529524
- Association between ANGPTL3, 4, and 8 and lipid and glucose metabolism markers in patients with diabetes. Harada M et al. PLoS One. 2021 Jul 22;16(7):e0255147.PMID: 34293055
- Changes in serum levels of angiopoietin-like protein-8 and glycosylphosphatidylinositol-anchored high-density lipoprotein binding protein 1 after ezetimibe therapy in patients with dyslipidemia. Ideishi A et al. Clin Chim Acta. 2020 Nov;510:675-680.PMID: 32858055
- Lipoprotein profile and lipid metabolism of PXB-cells®, human primary hepatocytes from liver-humanized mice: proposal of novel in vitro system for screening anti-lipidemic drugs. Hata K et al. Biomed Res. 2020;41(1):33-42.PMID: 32092738
- Circulating Angptl3 and Angptl8 Are Increased in Patients With Hypothyroidism. Yang L et al. Biomed Res Int. 2019 Jul 17;2019:3814687.PMID: 31380419
- Association of circulating ANGPTL 3, 4, and 8 levels with medical status in a population undergoing routine medical checkups: A cross-sectional study. Morinaga J et al. PLoS One. 2018 Mar 14;13(3):e0193731.PMID: 29538435
Note: Retrieve by PMID number in displayed by abstract: http://www.ncbi.nlm.nih.gov
FAQ
FAQ
-
Q.Is composition of EIA buffer of each ELISA kit all same? Can it be mixed to use?
ELISA common FAQ -
A.No it isn't. As constitute of each EIA buffer is different, it cannot be mixed with other lots or EIA buffers contained in other kind of ELISA kits.
-
Q.What is the composition of concentrated wash buffer?
ELISA common FAQ -
A.It contains ordinary Tween and phosphate buffer (0.05% Tween-20 in PB).
-
Q.What is the feature of the plate?
ELISA common FAQ -
A.We use plate that is flat bottom and removable strip type plate (8wellx 12 strips).
-
Q.Can I re-use standard after reconstitution?
ELISA common FAQ -
A.Not recommended to re-use standard after reconstitution. Please use it at once after the reconstitution.
Please note that there are some exceptions. One time freeze-thaw the standard is acceptable for use after reconstitution for some ELISAs.
Please check the details on each product datasheet. -
Q.What is different between reagent blank and test sample blank?
ELISA common FAQ -
A.Reagent blank means a well is only added EIA buffer and the purpose is confirming whether the Test sample value is influenced by lack of washing process or other operations. Test sample blank means a well is added EIA buffer and HRP antibody and the purpose is to calculate the background.
-
Q.How many samples can be measured by this kit?
ELISA common FAQ -
A.The pre-coated plate contained in our ELISA kit is 96 wells plate. We recommend to use 16 wells (2 slits) for standard and 80 wells (10 slits) for 40 samples in duplicate.
-
Q.What is LOD (Limit of Detection)?
ELISA common FAQ -
A.It (LOD) is defined as sensitivity that is calculated using the NCCSL method. Please refer to a datasheet of each product.
-
Q.What is LOQ (Limit of Quantification)?
ELISA common FAQ -
A.It (LOQ) is the lowest value of measurement (standard) range. Please refer to a datasheet of each product.
-
Q.What is the definition of Over Night (O/N) reaction?
ELISA common FAQ -
A.It means that the reaction is required more than 16 hours unless otherwise specifically defined it on a datasheet of each ELISA product.
-
Q.What is the specification of quality control for ELISA product release?
ELISA common FAQ -
A.The information of specification is available on individual lot specific CoA. Please contact us with your reference lot number for obtaining of specific CoA.
-
Q.What is the number (e.g. 432143214321) at the edge of strips of the plate?
ELISA common FAQ -
A.According to the plate maker (ThermoFisher), it does not have any specific meaning as it is just the number of molds.
-
Q.How to wash an ELISA plate?
ELISA common FAQ -
A.Washing it by an auto-washer is highly recommended.
If it is not available, please refer to the demo video (only 2 mins) using a washing bottle. -
Q.The wells turned black during the test with the kit.
ELISA common FAQ -
A.It is possible that the wells were not washed sufficiently during the washing process after the HRP-labeled antibody reaction.
Be sure to wash the wells enough times as described in the data sheet with washing buffer of more than 350 µL.